{"id":12122,"date":"2021-09-29T05:34:25","date_gmt":"2021-09-29T05:34:25","guid":{"rendered":"https:\/\/dev.ingenieros-im3.com\/uncategorized\/digital-signal-transmission\/"},"modified":"2022-11-30T18:04:42","modified_gmt":"2022-11-30T18:04:42","slug":"digital-signal-transmission","status":"publish","type":"post","link":"https:\/\/www.ingenieros-im3.com\/en\/noticias\/digital-signal-transmission\/","title":{"rendered":"Digital Signal Transmission"},"content":{"rendered":"<\/p>\n<p>29\/09\/2021<\/p>\n<\/p>\n<p class=\"MsoNormal\"><strong><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">Foreword:\u00a0<\/span>We continue to celebrate the month of electrical engineering, within the cycle of the 40th anniversary of Im3.<\/strong><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>Although this news and its continuation refer to the transmission of digital signals through electrical and optical cables, the concepts and laws referred to constitute the conceptual basis for the development of communication projects by means of electromagnetic waves in any medium, including fields of maximum interest to Im3 such as: communications in substations and digital networks, LiDAR technology, carrier wave, microwave, geo-radar (GPR), 5G communications, Wi-Fi, IoT, FTTH deployment or implementation of smart metering systems. And even the behavior of lines and earth meshes against atmospheric discharges.<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>The propagation of an electrical signal in the form of an electromagnetic (EM) wave through conductive cables travels at a speed of approximately:<\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 80-90% the speed of light in vacuum (c)<\/span><\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 2.4-2.7 x 108 m \/ s<\/span><\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 24-27 cm \/ ns<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>On the other hand, every electrical pulse transmitted in a conducting medium can be represented as the sum of its sinusoidal components of different frequencies (Fourier&#8217;s theorem).<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>And due to the impedance of the cable (mainly its inductance), the different frequency components of electrical signals travel at different speeds and experience different attenuations.<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>Attenuation is the gradual reduction in the intensity of the wave through the medium, which in sinusoids that move linearly consists of the decrease in the amplitude of the wave between the emission and its receiver.<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span><span lang=\"EN-US\">Power attenuation <\/span><span lang=\"ES-CL\">\u03b1<\/span><span lang=\"EN-US\"> is calculated in decibels (dB) as <\/span><span lang=\"ES-CL\">\u03b1<\/span><span lang=\"EN-US\"> = 10 log (P_reception \/ P_emission)<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">= 10 log (R*I_ reception^2 \/ R*I_ emission ^2)  = 10 log ((I_reception \/ I_emission)^2) <\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">= 2*10 log (I_reception \/ I_emission)  = 20*log (I_reception \/ I_emission) <\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>The attenuation in the transmission of a signal usually oscillates between 0dB (without the presence of attenuation) and -40dB (see graphic in the image of the news). This range or system gain can be as wide as 120dB depending on the technology. For reference:<\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 An attenuation of -6.02 dB corresponds to a reduction of half (1\/2) the amplitude of the signal (respectively a quarter of the power).<\/span><\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 And an attenuation of -9.54 dB, represents a reduction of one third (1\/3) of its amplitude.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>On the other hand, the fact that the waves travel at different speeds means that they reach the receiver with time lags, which increase in direct proportion to the length of the conductor (distance between emitter and receiver).<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>This &#8216;low pass&#8217; effect causes both the rising and falling ends of the pulse to deviate in time, a phenomenon known as dispersion (frequency-dependent phase velocity) and which, together with interference, could cause jitter (which is the difficulty to recover the clock from a signal)<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>Since the exposed phenomena are limiting factors for the integrity of the signal reception, they will condition the maximum length of the conductor (L) for each transmission frequency (or channel bandwidth). And, if we include external noise in the equation, therefore, it limits your channel transmission capacity.<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>Recall that, according to Shannon&#8217;s theorem, the capacity of an ideal channel in bits\/s is equal to C = B * log2 (1 + S \/ N), where B is the bandwidth of the channel in Hz, S is the power of the useful signal in W and N the power of the noise present in the channel in W. This means that, if the medium is dedicated, there would be no limit to the bandwidth by the medium. But this is not the case, even in the absence of attenuation.<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span><span lang=\"EN-US\">As a &#8216;rule of thumb&#8217;, for traditional cabling, we can say that the transmission of data, in baseband, through the channel will be technically feasible when the length of the line is reduced compared to the wavelength of the signal ( <\/span><span lang=\"ES-CL\">\u03bb<\/span><span lang=\"EN-US\">), approximately L &lt;<\/span><span lang=\"ES-CL\">\u03bb<\/span><span lang=\"EN-US\">\/100.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\">For example, for a copper conductor of L = 100 meters, the maximum data transmission frequency would be that in which <\/span><span lang=\"ES-CL\">\u03bb<\/span> <span lang=\"EN-US\">= 100\/100 = 1m, which for a propagation speed of 2.55 x 108  would correspond to an fmax \u2248 2.55 x 108  \/ 1  = 255 x 106  = 255 MHz.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>To overcome this rate limitation, the materials selected for the construction of the wiring evolve to improve their standards. In simple terms, the new standards seek among other things: to eliminate dispersion, by building a medium with a constant phase velocity, up to at least the order of magnitude of the bandwidth of the bit rate (or baseband).<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span><span lang=\"EN-US\">The above frequency corresponds to a period of T = 1 \/ 255M Hz = 3.9215 x 109 sec = 3.9215 x 106 ms = 3.9215 x 103 <\/span><span lang=\"ES-CL\">\u03bc<\/span><span lang=\"EN-US\">s = 3.9215 ns (equivalent to the time it takes for light to travel 1.17 meters in vacuum)<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>Currently, for Ethernet networks with twisted pair cables, the higher technology categories have the following bandwidths:<\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 Cat7 (600 MHz) category F according to ISO EN 50173<\/span><\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 Cat7A (1000 MHz) category FA according to ISO EN 50173<\/span><\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 Cat 8 \/ 8.1 (2000 MHz) ISO \/ IEC 11801-1: 2017<\/span><\/p>\n<p class=\"MsoNormal\" style=\"padding-left: 30px;\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u2022 Cat 8.2 (2000 MHz) ISO \/ IEC 11801-1: 2017<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span>Important: The above categories can be used with guarantees of signal integrity as long as the cable lengths are less than 100 meters.<\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span><span style=\"color: #0070c0;\">References:<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"color: #0070c0; mso-ansi-language: EN-US;\">Signal Integrity vs. Transmission Rate and Cable Length for Rs-485 Transceivers, Application Report SLLA375 &#8211; September 2017, Texas Instruments<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"color: #0070c0; mso-ansi-language: EN-US;\"><a href=\"https:\/\/www.ti.com\/lit\/an\/slla375\/slla375.pdf?ts=1632497182787&amp;ref_url=https%253A%252F%252Fwww.google.com%252F\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0070c0;\">https:\/\/www.ti.com\/lit\/an\/slla375\/slla375.pdf?ts=1632497182787&amp;ref_url=https%253A%252F%252Fwww.google.com%252F<\/span><\/a><\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"color: #0070c0; mso-ansi-language: EN-US;\">Signals, The Science of Telecommunications, John R. Pierce and A. Michael Noll, Editorial Revert\u00e9, S.A., 1995<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\">\u00a0<\/span><\/p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>29\/09\/2021 Foreword:\u00a0We continue to celebrate the month of electrical engineering, within the cycle of the 40th anniversary of Im3. \u00a0Although this news and its continuation refer to the transmission of&#8230;<\/p>\n","protected":false},"author":894,"featured_media":5702,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-12122","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-noticias"],"_links":{"self":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts\/12122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/users\/894"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/comments?post=12122"}],"version-history":[{"count":1,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts\/12122\/revisions"}],"predecessor-version":[{"id":12689,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts\/12122\/revisions\/12689"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/media\/5702"}],"wp:attachment":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/media?parent=12122"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/categories?post=12122"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/tags?post=12122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}