{"id":12234,"date":"2022-06-17T04:58:02","date_gmt":"2022-06-17T04:58:02","guid":{"rendered":"https:\/\/dev.ingenieros-im3.com\/uncategorized\/cade-simu-applied-to-control-systems-in-substations\/"},"modified":"2022-11-30T18:04:54","modified_gmt":"2022-11-30T18:04:54","slug":"cade-simu-applied-to-control-systems-in-substations","status":"publish","type":"post","link":"https:\/\/www.ingenieros-im3.com\/en\/noticias\/cade-simu-applied-to-control-systems-in-substations\/","title":{"rendered":"CADe Simu applied to Control Systems in Substations"},"content":{"rendered":"<\/p>\n<p>17\/06\/2022<\/p>\n<\/p>\n<p class=\"MsoNormal\"><span lang=\"PT-BR\">The main function of a Control System in an electrical substation is to supervise, control and protect electrical installations.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"PT-BR\">A Control System in a Substation is implemented following a hierarchical architecture by levels:<\/span><\/p>\n<p class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo1;\"><!-- --><span lang=\"PT-BR\" style=\"mso-ascii-font-family: Calibri; mso-fareast-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri;\"><span style=\"mso-list: Ignore;\">\u2022<span style=\"font: 7.0pt 'Times New Roman';\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/span><\/span><\/span><!----><span lang=\"PT-BR\">Level 0: primary equipment and auxiliary services.<\/span><\/p>\n<p class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo1;\"><!-- --><span lang=\"PT-BR\" style=\"mso-ascii-font-family: Calibri; mso-fareast-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri;\"><span style=\"mso-list: Ignore;\">\u2022<span style=\"font: 7.0pt 'Times New Roman';\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/span><\/span><\/span><!----><span lang=\"PT-BR\">Level 1: bay controllers.<\/span><\/p>\n<p class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo1;\"><!-- --><span lang=\"PT-BR\" style=\"mso-ascii-font-family: Calibri; mso-fareast-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri;\"><span style=\"mso-list: Ignore;\">\u2022<span style=\"font: 7.0pt 'Times New Roman';\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/span><\/span><\/span><!----><span lang=\"PT-BR\">Level 2: centralized substation control.<\/span><\/p>\n<p class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo1;\"><!-- --><span lang=\"PT-BR\" style=\"mso-ascii-font-family: Calibri; mso-fareast-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri;\"><span style=\"mso-list: Ignore;\">\u2022<span style=\"font: 7.0pt 'Times New Roman';\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/span><\/span><\/span><!----><span lang=\"PT-BR\">Level 3: remote control and operation centers.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"PT-BR\">Due to the advancement of supervision and data collection systems, the control of substations has evolved from completely manual systems of local operation towards integration in Substation Automation Systems (SAS)<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"PT-BR\">The image of the news shows the scheme designed in CADe Simu for the selection of the Operating Modes for the opening\/closing maneuver of a high voltage switch in the 110 kV switchyard of a substation, which allows the visual verification of its operation.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"PT-BR\">The power switches, together with the disconnectors, the operating modes of the ONAN\/ONAF\/OFAF power transformer cooling systems, the Tap Changers and the Auxiliary Services configuration are the elements that allow the topology of the network and the working mode of its auxiliary systems to be modified.<\/span><\/p>\n<p class=\"MsoNormal\"><span lang=\"PT-BR\">Im3, creating engineering solutions for the future!<\/span><\/p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>17\/06\/2022 The main function of a Control System in an electrical substation is to supervise, control and protect electrical installations. A Control System in a Substation is implemented following a&#8230;<\/p>\n","protected":false},"author":894,"featured_media":8455,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-12234","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-noticias"],"_links":{"self":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts\/12234","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/users\/894"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/comments?post=12234"}],"version-history":[{"count":0,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/posts\/12234\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/media\/8455"}],"wp:attachment":[{"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/media?parent=12234"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/categories?post=12234"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ingenieros-im3.com\/en\/wp-json\/wp\/v2\/tags?post=12234"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}